FrigidAire Fridge - Improper Cooling
Model: LFTR2045VF9
Location: North Fort Myers, FL 33917
Repair Summary
Checked refrigerator for improper cooling. Customer stated that the freezer was maintaining some cooling, but the fresh food section was not cooling properly. Upon arrival, found the refrigerator unplugged. Inspected the door gaskets and verified that all doors were sealing properly. Advanced the defrost timer and bypassed the defrost bimetal to test the heating circuit. Found that the defrost heater would not activate, confirming a defective heater assembly.
Replaced the defrost heater assembly, which included a new defrost bimetal. Tested the defrost system and verified that the heater was activating and operating properly. Advised customer to allow 24 hours for the refrigerator and freezer compartments to reach their proper operating temperatures. Unit checks normal at this time.