Model: PFD95ESPW0GN

Location: Ave Maria, FL 34142


Repair Summary

Checked dryer for intermittent heating issues after the main control board and display board were previously replaced. Found the unit had lost its personality settings. Personality code 25 had been entered, but the customer continued experiencing intermittent no-heat concerns. Tested the dryer on Timed Dry and verified the vent and heating cycles were operating properly at the time of service. Contacted Tech Support to document the intermittent issue and determine the proper programming. With Tech Support assistance, successfully restored the correct personality settings. Retested operation and verified the dryer is now operating and heating properly. Advised the customer to continue monitoring the unit. Unit checks normal at this time.



 
 