GE Dryer - No Heat
Model: GTX22EASK1WW
Location: Ave Maria, FL 34142
Repair Summary
Checked dryer for no heat. Upon arrival, tested the dryer on Timed Dry and verified the unit is producing heat; however, heat is not exhausting properly and the dryer is cooling down extremely slowly. Attempted to perform the vent airflow test through the diagnostic application, but the application would not open due to a required update and could not be restored after reinstalling. Evaluated airflow manually and found very little heat or airflow exhausting through the vent. The heater could be heard cycling off as designed, but the internal temperature was only dropping approximately 1–2°F every 5–10 seconds, indicating a significant restriction in the external dryer vent system. Made the customer aware that the apartment complex’s dryer vent will need to be professionally cleaned/serviced. Dryer is producing heat; the remaining concern is related to restricted external vent airflow.