GE Fridge - Intermittent Cooling Issues
Model: GSE22ETHCBB
Location: Cape Coral, FL 33991
Repair Summary
Checked refrigerator for an intermittent fresh food cooling concern. Customer stated the fresh food section had reached approximately 55°F for one day but advised that it had returned to normal before arrival and was currently at 36°F. Removed the rear cover and verified the compressor and condenser fan motor are operating properly. Removed the freezer evaporator cover and confirmed the evaporator fan motor is running. Manually energized the defrost heater and verified it is also operating properly. At this time, all cooling and defrost components are functioning as designed and the refrigerator is maintaining proper temperature. The temporary temperature issue may have been related to an intermittent control issue or recent power fluctuations; however, no active failure could be duplicated at this time. Advised the customer to monitor the refrigerator for any recurrence. Unit checks normal at this time.