KitchenAid Fridge - No Cool In Freezer
Model: KRFC704FPS06
Location: Fort Myers, FL 33908
Repair Summary
Checked refrigerator for freezer not cooling properly. Upon arrival, measured the freezer temperature at approximately 36°F. Pulled the refrigerator out and found a piercing/tap valve had previously been installed on the compressor by another service company, indicating prior sealed-system work. Returned and replaced the filter drier and removed the existing piercing valve. Pressure tested all sealed-system connections with 155 PSI of nitrogen and found no leaks. Evacuated the system and initially charged with 1.98 oz of refrigerant according to specification; however, the compressor continued pulling the low side into a vacuum, requiring adjustment of the refrigerant charge until operating pressure stabilized. Advised the customer to place a bottle of water in the freezer and allow approximately 24 hours to determine whether proper freezing temperatures are restored. If the freezer fails to cool properly, the compressor will require replacement. Also replaced the lower left hinge roller. Customer will monitor the unit.