Repair Summary

Checked washer for not starting a cycle and failing to drain. Customer stated the washer was full of water and would not drain, requiring them to manually remove the water through the drain plug into a catch pan. Upon arrival, attempted a drain and spin cycle and verified voltage reaching the drain pump. Removed and inspected the drain pump and found the check valve stuck, along with excessive black sediment and debris obstructing the impeller. Replaced the drain pump with a new assembly.


After replacement, initiated another test cycle and found the drain pump would start briefly, then immediately stall and intermittently cycle on and off. Traced voltage from the main control board through the wiring harness and discovered a damaged wire midway through the harness, causing an intermittent electrical connection. Replaced the damaged wiring harness and retested the washer. Verified proper operation of all components, including filling to the correct water level, agitation, draining, and spinning. No error codes or water leaks detected. Unit checks normal at this time.



 
 