Samsung Fridge - Ice Maker Issues
Model: RF27CG5010S9AA
Location: North Fort Myers, FL 33917
Repair Summary
Checked refrigerator for ice makers not working. Connected HASS and ran the Weak Cooling Test, which showed abnormal temperatures in the freezer. Inspected the compressor compartment and found oil residue at the high-side coupler, indicating a refrigerant leak. Replaced the high-side coupler, service port, and filter drier. Pressurized the sealed system to 350 PSI with nitrogen and bubble checked all connections; no leaks were found. The system lost approximately 2.4 PSI over 15 minutes. Evacuated the system to approximately 600 microns and recharged the refrigerator with 86 grams of R600a refrigerant. Cycled the ice maker and verified it completed the cycle and filled with water properly. Advised the customer to allow approximately 24 hours for the refrigerator to regulate and for normal ice production to resume. Unit checks normal at this time.