top of page

Samsung Fridge - Insufficient Cooling

Nov 10
1 min read

Model: RT70F18LASRAA

Location: Fort Myers, FL 33907


Repair Summary

Checked refrigerator for insufficient cooling. Upon inspection, identified a refrigerant leak at the condenser Lokring connection, causing a loss of refrigerant and poor cooling performance. Repaired the leaking connection and replaced the filter drier. Pressurized the sealed system and performed a pressure test, confirming the system held pressure with no leaks detected.


Evacuated the sealed system and recharged it with the manufacturer-specified refrigerant charge. Tested refrigerator operation and confirmed the sealed system was functioning properly with no abnormalities detected. Advised customer to allow up to 24 hours for temperatures to stabilize and to continue monitoring cooling performance. Unit checks normal at this time.



 
 