top of page

Samsung Fridge - Low Ice Production

Oct 8
1 min read

Model: RF70H30GERAA

Location: Fort Myers, FL 33913


Repair Summary

Checked refrigerator for low ice production. Customer stated the refrigerator was producing only approximately one batch of ice per day. Connected HASS and ran the Weak Cooling Test; temperatures were holding and cooling properly at the time of service. HASS history showed defrost cycles occurring approximately every 6–8 hours, which is more frequent than expected. Inspected the compressor compartment and sealed-system connections and found no visible oil residue or refrigerant leakage. Bubble tested the accessible connections with no leaks detected. Further inspection found the suction line freezing over, indicating a possible low refrigerant charge or restriction. A restriction could potentially be within the cabinet or through the three-way valve. Customer also reported that the ice maker was leaking water again. Forced the ice maker to cycle and observed water dripping after the fill cycle, indicating a defective ice maker seal. Replaced the ice maker and filter drier, pressure tested the sealed system, evacuated the system, and recharged it to the factory-specified charge. Advised the customer to monitor the refrigerator for approximately 24 hours for proper cooling and ice production. Unit checks normal at this time.



 
 