Repair Summary
Checked refrigerator for no cooling. Upon arrival, verified the compressor and fans were running. Ran HASS diagnostics and found no error codes. Completed the Weak Cooling Test, which showed elevated temperatures. Inspected the compressor area and found no visible oil or obvious signs of a refrigerant leak. Suspected a possible sealed-system leak and ordered a filter drier and plug check to pressure test the system. Returned and installed the ordered parts. During the initial pressure test, found the system was slowly losing pressure. Bubble tested the connections and found bubbles forming at the condenser coupler, confirming a refrigerant leak. Removed and replaced the leaking coupler. Pressurized the sealed system with 350 PSI of nitrogen and isolated it for 15 minutes. Found no bubbles at any repaired joints and recorded only a 0.6 PSI pressure drop, resulting in a passing pressure test. Evacuated the system to approximately 600 microns and recharged it according to factory specifications. Restored power and verified the compressor and all fans started properly. Set temperatures accordingly and advised the customer to allow approximately 24 hours for proper cooling temperatures to be reached. Unit checks normal at this time.