Model: RS27T5200SR/AA

Location: Lehigh Acres, FL 33974


Repair Summary

Checked refrigerator for no cooling. Upon arrival, found the refrigerator located in the garage. The compressor and condenser fan were operating, but there was no airflow in the freezer section. Connected HASS and found a C21 error code indicating a freezer evaporator fan failure. The HASS OQC test failed due to the fan error. Replaced the freezer evaporator fan motor and verified the error code cleared and proper airflow was restored. Further testing found the refrigerator was still not cooling properly due to a refrigerant leak at the condenser coupler. Determined a sealed-system repair was required and advised the customer to leave the refrigerator unplugged until the return visit so the system could reach room temperature for more accurate pressure testing. Returned and replaced the filter drier, service port, and high-side coupler. Pressurized the sealed system to approximately 350 PSI with nitrogen and bubble checked all accessible connections with no leaks found. The system lost approximately 1.6 PSI over 15 minutes. Evacuated the system to approximately 600 microns and recharged it with 84 grams of R600a refrigerant. Restored operation and verified the sealed system is operating properly. Advised the customer to allow approximately 24–48 hours for the refrigerator to reach proper temperatures and resume normal ice production. Unit checks normal at this time.



 
 