Samsung Fridge - No Cool
Nov 2
1 min read
Model: RF30BB620012AA
Location: Naples, FL 34105
Repair Summary
Checked refrigerator for no cooling. Upon arrival, found the circuit breaker turned off. Restored power and performed a HASS weak cooling test, which failed all tests. Inspected the sealed system and found oil residue near the condenser, indicating a refrigerant leak. Repaired the leaking connection and pressurized the system with 360 PSI of nitrogen. System held pressure for 25 minutes with no leaks detected.
Evacuated the sealed system and recharged with 2.75 oz of refrigerant. Ran HASS overall diagnostics, and all tests passed with no issues. Advised customer to allow 24 hours for proper cooling. Unit checks normal at this time.\