Samsung Fridge - No Cool
Model: RF25C5551SR/AA
Location: North Fort Myers, FL 33903
Repair Summary
Customer reported that the refrigerator was not cooling properly. Upon arrival, connected HASS and performed a weak cooling diagnostic test. Reviewed diagnostic graphs and identified abnormal temperature fluctuations in the freezer compartment. Further inspection of the sealed system revealed oil residue on the high-pressure side, indicating a possible refrigerant leak. Determined that the high-side couplers, filter drier, and service port required replacement.
Completed sealed-system repairs by replacing the high-side couplers, filter drier, and service port. Pressurized the system with nitrogen to 350 PSI and performed a bubble leak test on all accessible connections. During the initial 15-minute pressure test, observed a 6 PSI pressure drop. Recorded compartment temperatures of 18°F in the freezer and 46°F in the fresh food section and noted that temperature changes may have influenced pressure readings. Repeated the pressure test and observed a similar but slower pressure decline. Evacuated the sealed system to 600 microns and recharged with refrigerant according to factory specifications. Restored power and verified that the compressor and all fans were operating, with cool air circulating through the compartments. Adjusted temperature settings and advised the customer to allow 12–24 hours for cooling temperatures to stabilize and ice production to resume. Further monitoring is recommended due to the pressure loss observed during testing.