Thermador Ice Machine - No Ice

Nov 9
1 min read

Model: UDF0190A-161B

Location: Cape Coral, FL 33904


Repair Summary

Checked ice machine for reported failure to produce ice. Upon initial inspection, connected power and verified that the water reservoir filled and the circulation pump activated, allowing water to flow over the cold plate. However, the reservoir continued filling beyond its normal capacity, causing water to overflow into the drain. This sequence repeated three times before the unit displayed an error code. Reset the machine and manually shut off the water supply once the reservoir reached the proper level, allowing normal water circulation. Further testing confirmed that the refrigeration system was operating properly, with the cold plate temperature dropping from 65°F to below 30°F and ice beginning to form. Determined that the water level sensor and thermostat required replacement to correct the improper filling and cycling conditions.


Returned and replaced the defective water level sensor and thermostat. Restored power and verified that the reservoir filled to the proper level without overflowing. Confirmed that the unit correctly detected the water level and circulated water over the cold plate without leaks. Observed the refrigeration system operating and ice beginning to form normally. Left the ice machine running to allow continued ice production and advised that property management would return to verify that the unit produces a full bin of ice. All checks passed during testing, and the ice machine is operating normally at this time, pending confirmation of a complete ice production cycle.



 
 