Whirlpool Dryer - Stopping Cycle Early
Model: WED5010LW1
Location: Cape Coral, FL 33909
Repair Summary
Customer’s complaint is that the dryer stopped prematurely during a cycle, leaving clothes wet. Upon inspection, verified proper incoming voltage of 120V from L1 to neutral, 120V from L2 to neutral, and approximately 220–240V between L1 and L2. Operated the dryer for approximately 20 minutes and confirmed proper heating. Inspected the circuit breaker in the garage and found no signs of overheating. During initial testing, the motor briefly slowed or stopped for a moment before resuming normal operation.
Returned to the customer's home and operated the dryer on Timed Dry for approximately 45 minutes. The dryer completed the entire cycle without shutting off prematurely and maintained proper heating. Verified incoming voltage remained within specifications, and the circuit breaker temperature stayed around 90°F with no overheating. Contacted Whirlpool Tech Line to review all findings. Customer had been using the Normal cycle, which relies on moisture sensing and automatically adjusts cycle duration. Tech Line advised that the customer's concern may have been related to cycle selection or moisture sensor operation rather than a motor failure. Successful completion of the Timed Dry cycle indicates the motor is operating properly during testing. No premature shutdown could be duplicated during the follow-up visit. Advised customer of all findings and proper cycle selection.