Repair Summary

Customer reported that the freezer was cooling inconsistently, with the compressor periodically shutting off and restarting during operation. Upon arrival, inspected the freezer and found the compressor and evaporator fan running normally. Tested the defrost heater for resistance and confirmed readings were within manufacturer specifications. Inspected the evaporator and verified a proper frost pattern, indicating normal cooling performance while the compressor was operating. During further testing, observed the compressor shut off unexpectedly. Performed voltage testing and confirmed that the compressor was not receiving the required 120V supply from the main control board, indicating an intermittent control board failure.


Removed and replaced the defective main control board. Restored power and verified that the compressor and evaporator fan were operating properly.

Confirmed that the freezer resumed normal cooling operation following the repair. All components tested were functioning as designed, and no additional issues were observed at this time. Advised the customer to continue monitoring freezer temperatures to ensure consistent cooling performance.



 
 