Whirlpool Fridge - No Cool
Model: WRT318FMDB00
Location: Bonita Springs, FL 34134
Repair Summary
Checked refrigerator for no cooling. Upon arrival, found the refrigerator turned off. Restored power and inspected the evaporator frost pattern. After approximately 15 minutes of operation, found only a small amount of frost developing at the top of the evaporator coil with no complete frost pattern, indicating the sealed system was low on refrigerant. Ordered the necessary sealed-system parts. Installed all ordered parts and pressure tested the sealed system with 160 PSI of nitrogen. Allowed approximately 10 minutes for the pressure to settle and verified the system held with no leaks detected. Discharged the nitrogen, evacuated the sealed system to a proper vacuum, and charged the refrigerator with 4.16 oz of refrigerant according to factory specifications. Verified operating pressures were within normal range after the repair. Advised the customer to allow approximately 24 hours for the refrigerator to cool down and temperatures to stabilize.