top of page

Whirlpool Fridge - Slow Ice Production / No Cool

12 hours ago
1 min read

Model: WRS315SDHM13

Location: Alva, FL 33920


Repair Summary

Checked refrigerator for slow ice production and fresh food section not cooling properly. Upon arrival, found the unit operating in a defrost cycle and documented temperature readings with uploaded pictures. Customer stated the freezer eventually reaches 1°F and the fresh food section reaches 36°F. Customer had the refrigerator set to its coldest settings. Educated customer on how frequent door openings, normal defrost cycles, and blocked air passages can cause temperature fluctuations and uneven cooling. Inspected the compressor area and evaporator for refrigerant leaks using bubble leak detection solution. No leaks were found. After the defrost cycle completed, observed the evaporator coil developing frost from the bottom upward, indicating refrigerant circulation and no obvious signs of refrigerant loss.


Replaced the evaporator fan motor to improve airflow and cooling performance. Educated customer that the ice maker may take up to 72 hours to fill the ice bin under normal conditions without ice being removed. Explained that frequent daily ice usage may prevent the bin from reaching full capacity. Reviewed proper airflow, temperature settings, and normal refrigerator operation with the customer. Customer was advised to monitor cooling performance and ice production following the repair.



 
 