top of page

Whirlpool Fridge - Tripping GFCI Outlet

5 days ago
1 min read

Model: WRS325SDHZ01

Location: Fort Myers, FL 33913


Repair Summary

Customer’s complaint is that the garage refrigerator is repeatedly tripping the GFCI-protected outlet. Upon inspection, checked the refrigerator’s electrical components, including the compressor and capacitor, and found both operating properly during testing. Ran the unit through diagnostics and manually activated the defrost heater without any issues or electrical trips. Tested the compressor three separate times, and it started and operated normally during each test. No electrical failure or abnormal operation could be duplicated at this time.


Advised the customer that the issue may be related to the GFCI protection or an intermittent electrical fault. Recommended having a licensed electrician inspect the outlet and circuit to verify proper operation and determine whether the existing GFCI protection is required. Explained that if the compressor begins tripping the circuit breaker, further diagnosis would be necessary to determine whether an intermittent locked-rotor condition is occurring, which could require compressor replacement. At this time, the compressor and all tested refrigerator components are operating normally. Customer was advised of all findings and recommendations.



 
 
bottom of page