Whirlpool Fridge - Weak Cooling
Model: WRQA59CNKZ
Location: Fort Myers, FL 33905
Repair Summary
Checked refrigerator for weak cooling. Upon arrival, measured freezer temperatures ranging from 30°F to 38°F, indicating inadequate cooling. Inspected the rear of the refrigerator and found extensive sulfur-related corrosion affecting multiple copper refrigerant lines. Customer has well water, which may be contributing to the sulfur exposure and corrosion. Determined that a sealed system repair was necessary and ordered the required parts.
Returned and performed the sealed system repair, replacing the filter drier. During inspection, found oil residue around the original filter drier, indicating a possible refrigerant leak. Pressurized the sealed system with 240 PSI of nitrogen and monitored pressure for approximately 15 minutes, with no leaks detected during testing. Evacuated the system and recharged with 2.75 oz of refrigerant. Completed the repair and verified operation. Informed the customer of the repairs performed and the existing sulfur-related corrosion. Unit checks normal at this time.