Samsung Fridge - No Cool
- 2 days ago
- 1 min read
Model: RF28T5001SR/AA
Location: Naples, FL 34119
Repair Summary
Checked refrigerator for no cooling. Upon arrival, found the unit plugged in but with no airflow and the compressor not running. Connected HASS and ran a service diagnostic report, which showed the refrigerator had not been cooling for over a week and had an 84C error code indicating a locked compressor. The inverter board was also flashing four LEDs, indicating an inverter-related fault. Determined the unit required a new compressor and main control board. Returned and installed the ordered components. Pressure tested the sealed system with 200 PSI of nitrogen and verified minimal pressure loss, resulting in a passing pressure test. Evacuated the system to approximately 600 microns and recharged it according to factory specifications. Restored power and verified the compressor and all fans started properly. Set the temperatures accordingly and advised the customer to allow approximately 24 hours for proper cooling temperatures to be reached. Unit checks normal at this time.



