Samsung Fridge - No Ice
Model: RF32CG5400SRAA Location: Bokeelia, FL 33922 Repair Summary Checked refrigerator for the top ice maker not producing ice. Upon arrival, connected HASS and ran the Weak Cooling Test, confirming both the fresh food and freezer sections are cooling properly. Found a stored error code related to the ice maker. Tested the IR sensor and verified it is operating properly. Both freezer ice makers are functioning correctly, and verified good water pressure to the refrigerator. C


GE Dryer - No Heat
Model: PTD60EBSR0WS Location: Fort Myers, FL 33905 Repair Summary Checked dryer for not heating properly. Customer stated the dryer barely gets hot. Started the dryer on a Time Dry cycle and verified the drum was rotating and the interior was heating properly, indicating the heating element is functioning. Inspected the exterior vent, which is located directly on the opposite side of the wall, and found no airflow. Further inspection of the duct and lint filter found a large


Samsung Fridge - Water Pitcher Overfilling
Model: RF29BB8600QLAA Location: Fort Myers, FL 33966 Repair Summary Checked refrigerator for the water pitcher overfilling. Upon arrival, connected HASS and checked for stored error codes. Found errors related to the ice maker and the water pitcher housing sensor. Ran the HASS Weak Cooling Test, which passed with no issues. Tested the water pitcher and found it initially filled to the proper level; however, after reaching the correct water level, it began filling again, indic


Whirlpool Dishwasher - Dishes Not Drying Properly
Model: WDT710PAHZ1 Location: Punta Gorda, FL 33982 Repair Summary Checked dishwasher for dishes not drying properly. Customer stated all other functions are operating normally. Upon arrival, placed the dishwasher into service mode and found no error codes. Ran a complete diagnostic test that checked all major components, including activation of the heating element at the end of the test cycle. Verified the heating element reached approximately 180°F and was able to melt an ic


Samsung Dryer - Burning Odor & Extended Drying Times
Model: DVE47CG3500VA3 Location: Bokeelia, FL 33922 Repair Summary Checked dryer for burning odor and extended drying times. Customer stated the dryer takes approximately two hours to dry clothes. Connected HASS and found no stored error codes. Ran the HASS Overall Performance Test and received a 90C error, after which the dryer stopped. Repeated the test with the dryer vent disconnected, and the test passed successfully. Performed a CPS airflow test and found the reading abov


LG Fridge - Door Issues & Abnormal Noises
Model: LF29S8365S Location: Lehigh Acres, FL 33971 Repair Summary Checked refrigerator for the right-side door not closing automatically and making an abnormal noise when closing. Upon inspection, determined the right-side automatic door-closing mechanism is defective and requires replacement. The required replacement part is currently unavailable. Contacted the warranty company and provided the findings. The warranty company instructed us to close the work order and will con


LG Washer - Intermittent Improper Water Filling
Model: WT7405CW Location: Cape Coral, FL 33904 Repair Summary Checked washer for intermittent improper water filling. Customer stated the washer does not fill properly on every load. Upon arrival, ran diagnostics and found no stored error codes. Ran the washer through an automatic test cycle, which completed successfully with no issues. Checked the hot and cold water supply and verified good water pressure with no restrictions. Tested the washer through the fill, wash, drain,


Samsung Washer - Substance & Damage On Console
Model: WA52DG5500AW Location: Lehigh Acres, FL 33976 Repair Summary Checked washer for a substance and damage on the exterior of the console. Customer stated she believed the substance was coming from inside the washer. Removed the rear panel of the console and inspected the interior, finding it clean with no evidence of any substance or leakage originating from inside the console. The damage appears to have been caused by something being spilled or dropped onto the top of th


Whirlpool Fridge - Cubed Ice Not Dispensing Properly
Model: WRS325SDHW08 Location: Naples, FL 34104 Repair Summary Checked refrigerator for cubed ice not dispensing properly and the dispenser getting stuck. Upon arrival, found the spring inside the ice bucket was not positioned correctly, causing the dispensing mechanism to bind. Adjusted the spring and dispenser components and verified both cubed and crushed ice were dispensing properly. Replaced the dispenser assembly due to the previous sticking issue. Tested the refrigerato


Samsung Washer / Dryer Combo - Display Issues
Model: WD90F53AVBUS Location: Lehigh Acres, FL 33972 Repair Summary Checked washer/dryer combo for the display going blank, not responding, and having distorted colors. Upon inspection, verified proper DC voltage was being supplied to the display assembly. Determined the display assembly was likely defective and replaced it. Tested the new display and verified all keys and functions are responding properly, the display remains powered, and the colors are displaying correctly.


Maytag Washer - Display & Cycle Selection Issues
Model: MHW8630HW1 Location: Naples, FL 34108 Repair Summary Checked washer for display and cycle selection issues. Upon arrival, inspected the washer and entered test mode. Verified proper water flow into the unit and confirmed the washer fills, washes, and drains properly. The washer completed the available test functions without operational issues. Several stored error codes were found related to the lid lock, water flow, and oversudsing, but none of these conditions were p


GE Washer / Dryer Combo - Loud Noise / Water Leaking / Not Drying Properly
Model: PFQ97HSPV0DS Location: LaBelle, FL 33935 Repair Summary Checked washer/dryer combo for loud noise, water leaking, and not drying properly. Upon arrival, found water leaking from the front door seal. The door seal is slightly warped and leaving a gap, so a new door seal will be required to correct the leak. Also found the lint trap assembly damaged, causing the lint tray to fit loosely and not seal properly. This is affecting airflow through the condenser and blower exh


Samsung Range - Oven Not Reaching Proper Temp
Model: NE59M4310SS/AA Location: Bonita Springs, FL 34134 Repair Summary Checked oven for not reaching the proper temperature. Upon arrival, tested the temperature sensor and verified the resistance reading was within specifications. Tested both bake and broil heating elements and found both operating within specifications. Started a heating cycle and initially observed the oven reaching approximately 280°F. After several minutes, the oven continued through another preheat cyc


Midea Fridge - Water Leaking
Model: MRF27I6BST Location: Fort Myers, FL 33967 Repair Summary Checked refrigerator for leaking water. Upon arrival, found the water supply to the refrigerator turned off. Customer restored the water supply, and initial inspection with the filter removed showed no visible leakage from the filter housing. Dispensed approximately 10 large glasses of water and found no leaks until shortly before leaving, when water was observed coming from underneath the front of the refrigerat


Samsung Fridge - Ice Maker Issues
Model: RF32CG5400SRAA Location: Cape Coral, FL 33909 Repair Summary Checked refrigerator for the Ice Bites ice maker not working. Connected HASS and verified the cooling system is operating properly with no cooling issues found. Cycled both ice makers and found the regular cube ice maker completed its cycle and filled with water properly. The Ice Bites ice maker cycled but did not fill because the ice maker fill tube was frozen. Replaced the frozen fill tube and retested the


Whirlpool Washer - Drain Pump Running After Cycle Starts
Model: WTW4816FW3 Location: Fort Myers, FL 33913 Repair Summary Checked washer for the drain pump running immediately when a cycle is started. Upon inspection, determined the condition is consistent with a faulty pressure-sensing circuit that is not properly identifying the water level. As a safety feature, the washer activates the drain pump when the control cannot properly determine the water level to help prevent an overflow. Verified that this model has a service bulletin


Samsung Fridge - Display Blinking & Showing Error Codes
Model: RF32FMQDBSR/AA Location: Fort Myers, FL 33912 Repair Summary Checked refrigerator for display blinking and showing error codes. Upon arrival, found the display continuously blinking with two stored error codes related to the ice room: one indicating an ice maker issue and another indicating a drain issue. Inspected the ice room and found it completely frozen over, with the ice bucket stuck in place. Explained the required repairs and findings to the customer. Customer


Maytag Washer - Not Starting
Model: MVW6500MBK0 Location: Cape Coral, FL 33909 Repair Summary Checked washer for not starting. Upon arrival, attempted to start the washer and found the Sensing light continuously blinking with no error codes displayed. Further testing indicated the main control was not properly detecting the lid lock. Tested the lid lock and measured approximately 74 ohms, which is within the manufacturer's specified range of 50–160 ohms. Customer stated the main control board had been re


Samsung Fridge - No Ice & Water Leaking Into Fresh Food Section
Model: RF23CB9900QKAA Location: Fort Myers, FL 33912 Repair Summary Checked refrigerator for no ice production and water leaking into the fresh food section. Upon arrival, found significant ice buildup around the crisper drawers. Further inspection found the water filter housing slowly leaking into the crisper area each time the ice makers fill. Also found the ice maker fill tube frozen over. Ran the HASS Weak Cooling Test and verified refrigerator temperatures are operating


Samsung Fridge - No Cool
Model: RS27T5200SR/AA Location: Lehigh Acres, FL 33972 Repair Summary Checked refrigerator for no cooling. Upon arrival, found both the freezer and fresh food sections at approximately 33°F. Connected HASS and ran the Weak Cooling Test, which confirmed the unit was maintaining proper temperatures. Ran the HASS OQC test and verified all other components were operating properly. Inspected the compressor compartment and found traces of oil at the condenser coupler, indicating a